MultiBoard signal integrity tests


We performed signal integrity tests for some nets on the Pulsar Board together with
HotLink Rx and Tx mezzanine cards using the IS_MultiBoard  tool by Mentor Graphics.

Most of the IBIS models were vendor supplied.
The IBIS models for Altera 20K400 were generated with Quartus II.
For the 1mm FH Mezzanine (IEEE 1386), BTB, Surface Mount connectors
we used vendor supplied Lumped Constant Model.
 

Some examples:
 

  •  LOGIC1_CDF_clkBus0_0.pdf
  •  Logic1_F1data0_in_01.psd - with 0 Ohm series resistor
  •  Logic1_F1data0_in_33.psd - with 33 Ohm series resistor
  •  Logic1_F1data0_out_01.psd - with 0 Ohm series resistor
  •  Logic1_F1data0_out_33.psd - with 33 Ohm series resistor
  •  Logic1_LWEN_n_out_01.pdf - with 0 Ohm series resistor
  •  Logic1_LWEN_n_out_33.pdf - with 33 Ohm series resistor

  •  

     
     
     
     
     
     
     



     
    For questions regarding this page contact Mircea Bogdan.
    bogdan@frodo.uchicago.edu
    Revised:8/16/02.